Hydraulic and Organic Loadings...

Question - 1 of 10 a b c d
Where in the plant will an organic overload cause problems ? The settling tank The chlorination contact tank The aeration tank The sludge holding tank
Question - 2 of 10 a b c d
Which operation control test would give the best indications of an organic overload ? The pH test The dissolved oxygen test The residual chlorine test There is no test which will indicate an organic overload
Question - 3 of 10 a b c d
During low flow periods, it is desirable to maintain the dissolved oxygen concentration at a level ; 2.0 - 3.0 mg / L 0.1 - 0.2 mg / L 1.0 - 2.0 mg / L Over 3.0 mg / L
Question - 4 of 10 a b c d
The minimum amount of dissolved oxygen that should exists during peak flow period is ; 0.5 mg / L 0.1 mg / L 0.2 mg / L 0.4 mg / L
Question - 5 of 10 a b c d
What action should you take when an organic overload occurs ? The water spray foam control system should not be operated Increase the speed of the air blower to provide more air to the aeration tank Discontinue using surface skimmers Decrease the speed of the air blower to provide less air to the aeration tank
Question - 6 of 10 a b c d
If an organic overload occurs without a noticable increase in daily flow, the problem may be due to ; Storm water infiltration into sewer pipes Industrial organic waste being discharged into the sewer Insufficient aeration Excessive aeration
Question - 7 of 10 a b c d
Another type of overload that you may experience is a temporary hydraulic overload and will cause problems that may be noticed first in which unit of the plant ? The settling tank The chlorine contact tank The aeration tank The sludge holding tank
Question - 8 of 10 a b c d
A hydraulic overload would have what effect on the plant ? Septic condition Will have no effect on the plant Could wash out practically all of the sludge Excessive foaming
Question - 9 of 10 a b c d
What action would help prevent this ? Discontinue using surface skimmer Increase the speed of the air blower to provide more air to the aeration tank Return all sludge possible There is no need to take any action
Question - 10 of 10 a b c d
Another recommended action is ; The water spray foam control system should not be operated Increase the speed of the air blower to provide more air to the aeration tank Return all sludge possible There is no need to take any action

                            Test is over... Please give your selections...!

Your name :
Your country :
Your job :
Your E - mail :
Your comment :
Your answers :
Question a b c d Question a b c d
1 2
3 4
5 6
7 8
9 10
Your command :                                

The results will be sent you including ;
(1) # true answers, (2) # wrong answers, (3) explanations for wrong answers and (4) final grade...

                                Back to test for getting new one...