Oracle® Process Manager and Notification Server Administrator's Guide
10g Release 2 (10.1.2) B13996-02 |
|
Previous |
Next |
This chapter describes OC4J configuration in the OPMN opmn.xml
file.
It features the following topics:
The following lines load and identify the OC4J process module. Management of OC4J processes by the process module are identified by the module id
.
<module path="$ORACLE_HOME/opmn/lib/libopmnoc4j.so"> <module-id id="OC4J" /> </module>
The following lines represent the minimum configuration for OC4J. Default values are assigned to all other configuration elements and attributes for OC4J.
<ias-component id="OC4J"> <process-type id="home" module-id="OC4J"> <port id="ajp" range="3301-3400" /> <port id="rmi" range="3101-3200" /> <port id="jms" range="3201-3300" /> <process-set id="default-island" numprocs="1"/> </process-type> </ias-component>
The complete configuration example in this section showcases the attributes of OC4J configuration that you can control. It contains all possible configuration elements and attributes that can be used with this component.
<ias-component id="OC4J" status="enabled" id-matching="false"> <environment> <variable id="LD_LIBRARY_PATH" value="$ORACLE_HOME/lib" append="true" /> </environment> <process-type id="home" module-id="OC4J"> <port id="ajp" range="3301-3400" /> <port id="rmi" range="3101-3200" /> <port id="jms" range="3201-3300" /> <process-set id="default-island" restart-on-death="true" numprocs="1"> <module-data> <category id="start-parameters"> <data id="java-options" value="-DTestVar=TestVal"/> <data id="oc4j-options" value=" "/> <data id="config-file" value="/my/config/dir/server.xml"/> <data id="java-bin" value="/my/javalocation/jdk/bin/java"/> </category> <category id="stop-parameters"> <data id="java-options" value="-DTestVar=TestVal"/> </category> <category id="restart-parameters"> <data id="reverseping-timeout" value="345"/> <data id="no-reverseping-failed-ping-limit" value="3"/> <data id="reverseping-failed-ping-limit" value="6"/> </category> <category id="urlping-parameters"> <data id="/j2ee/servlet/Spy" value="200"/> </category> <category id="security-parameters"> <data id="wallet-file" value="file:/private/user/ssl_cert/client_cert"/> <data id="wallet-password" value ="welcome1"/> </category> </module-data> <start timeout="300" retry="3"/> <stop timeout="300"/> <restart timeout="300"/> <ping timeout="30" interval="30"/> </process-set> </process-type> </ias-component>
This section describes the attributes that are specific for OC4J. This section also provides attribute descriptions of the attributes.
The OC4J attributes are described with the following format:
Title: This is the attribute name and value being defined. For example, id="OC4J".
Required: This field defines whether or not the attribute is required in the component definition.
Default: This defines the default value assigned to the attribute. The default value appears in the installed version of the opmn.xml
file or is assigned internally if the attribute is not present.
Valid values: If applicable, this field defines the valid values for the attribute. For example, OC4J
.
Path: This field defines in which elements the attribute can appear. For example, ias-component.
OC4J
ias-component
The id
name is required and cannot be changed. The id
must match the entry in the targets.xml
file or Application Server Control Console will not work.
environment
ias-component
The environment element can be specified at multiple levels within the Oracle Application Server component. This concept is important for the OC4J module because OC4J processes can be part of other Oracle Application Server components. In those cases, the required environment may have to be specified at the ias-component/process-type
level.
process-type
ias-component
For OC4J processes, the process-type
element is administratively equivalent to an OC4J instance.
module-id="OC4J"
ias-component/process-type
The module-id
associates the process with a module. For OC4J processes, this id
has to match the module-id
specified in the process module configuration for the OC4J module.
port
ias-component/process-type
The OC4J processes will not be started up unless port elements for ajp
and rmi
ports are configured. An OC4J process can be pinged at the ajp
ports; therefore one of the ports has to be configured. If both type of ports are configured, then the ajp
port is used for pinging. In addition to the ajp
and rmi
ports, you can also configure other port types that will be passed in to the OC4J process at the command line during process startup.
id="ajp"
ias-component/process-type/port
A port
element defining ajp
port
values is required.
id="rmi"
ias-component/process-type/port
A port
element defining rmi
port
values is required.
id="jms"
ias-component/process-type/port
A port
element defining jms
port
values is required.
range
ias-component/process-type/port
This attribute is used to specify valid port ranges, comma separated list of ports or a mix of both. For port selection by the operating system to select ports, specify 0 and the OC4J process will use a port provided by the system.
ias-component/process-type
process-set
element is administratively equivalent to an OC4J island.
id="start-parameters"
ias-component/process-type/process-set/module-data/
category
The start-parameters id
is a category that collects all of the parameters that are relevant for the startup of an OC4J process.
id="java-options"
ias-component/process-type/process-set/module-data/
category/data
OC4J requires that some java-options
be passed to start and stop commands. These options are derived internally by OPMN, are not part of the opmn.xml configuration, and cannot be overridden. Additional java-options
may be specified using this module data
element.
ias-component/process-type/process-set/module-data/
category/data
OC4J processes require options to be passed in as part of the start or stop commands to function correctly. These options cannot be overridden. In addition to these options, other options can be passed in through this module data
element. There is no default value for this data element.
ORACLE_HOME
/j2ee/<process-type id>/config/server.xml
ias-component/process-type/process-set/module-data/
category/data
The configuration file is an OC4J option in the start command. The default value for this data element is built from the $ORACLE_HOME
variable and OC4J instance name (process-type id
).
ORACLE_HOME
/jdk/bin/java
java.exe
ias-component/process-type/process-set/module-data/
category/data
The default value is the complete path to Java that is available in the installation. You can specify alternate paths to the Java executable. However, a valid version of Java will have to be used for the process to start up and work correctly.
ias-component/process-type/process-set/module-data/
category
The stop-parameters
id
is a category that includes all the parameters that are relevant for stopping an OC4J process.
ias-component/process-type/process-set/module-data/
category
The restart-parameters
category is used for defining parameters that will be used in death-detection.
id="reverseping-timeout"
300 seconds
ias-component/process-type/process-set/module-data/
category/data
The reverseping-timeout
value is the maximum allowable time between two notifications arriving from an OC4J process. As part of death-detection, the OC4J module performs forward pings on the process also. In the event that forward pings start failing, the reverse pings are taken into account in death-detection and restart.
id="no-reverseping-failed-ping-limit"
1
ias-component/process-type/process-set/module-data/
category/data
This module data
element defines the tolerance for failed forward pings in the event that reverse pings are also not being received (within the timeout period specified by reverseping-timeout data element). After the number of ping failures equals this limit, the process is deemed unresponsive and restarted by OPMN.
id="reverseping-failed-ping-limit"
3
ias-component/process-type/process-set/module-data/
category/data
This module data
element defines the tolerance for failed forward pings when reverse pings are succeeding. After the number of ping failures equals this limit, the process is deemed unresponsive and restarted by OPMN.
id="urlping-parameters"
ias-component/process-type/process-set/module-data/
category
The "urlping-parameters" id
enables users to specify URLs for ping operations as part of OC4J process ping operations. The data under this category consists of the URL and a valid HTTP return code. AJP13
protocol is used to directly connect to the OC4J process and the HTTP return code is validated against the configured code. If there are multiple URLs configured, failure in pinging any one of them will be considered a ping failure and the process will be restarted after the ping failures limit is exceeded.
id="/j2ee/servlet/Spy"
ias-component/process-type/process-set/module-data/
category/data
This is the URL in the OC4J process that will be pinged.
value="200"
ias-component/process-type/process-set/module-data/
category/data
The following is the HTTP code that results from ping operations to the configured URL.
<category id="security-parameters"> <data id="wallet-file"value="file:/private/user/ssl_cert/client_cert"/> <data id="wallet-password"value="welcome1"/> </category>
id="security-parameters"
ias-component/process-type/process-set/module-data/
category/
The OC4J process module can perform pings over SSL. The "security-parameters" id
is a category that enables users to specify the wallet file and password for such communication.
id="wallet-file"
ias-component/process-type/process-set/module-data/
category/data
The data id
whose value is the path to the wallet file (not including the filename).
value="file:/private/user/ssl_cert/client_cert"
ias-component/process-type/process-set/module-data/
category/data
The path to the wallet file (not including the filename). The data in the wallet file is used in SSL authentication during pinging.
id="wallet-password"
ias-component/process-type/process-set/module-data/
category/data
The data id
that specifies the wallet password.
value ="welcome1"
ias-component/process-type/process-set/module-data/